sungrow/modbus
2021-01-10 15:14:38 +11:00
..
.travis.yml remove vendor, but fork modbus pkg for now 2021-01-10 15:14:38 +11:00
api.go remove vendor, but fork modbus pkg for now 2021-01-10 15:14:38 +11:00
asciiclient.go remove vendor, but fork modbus pkg for now 2021-01-10 15:14:38 +11:00
client.go remove vendor, but fork modbus pkg for now 2021-01-10 15:14:38 +11:00
crc.go remove vendor, but fork modbus pkg for now 2021-01-10 15:14:38 +11:00
LICENSE remove vendor, but fork modbus pkg for now 2021-01-10 15:14:38 +11:00
lrc.go remove vendor, but fork modbus pkg for now 2021-01-10 15:14:38 +11:00
modbus.go remove vendor, but fork modbus pkg for now 2021-01-10 15:14:38 +11:00
README.md remove vendor, but fork modbus pkg for now 2021-01-10 15:14:38 +11:00
rtuclient.go remove vendor, but fork modbus pkg for now 2021-01-10 15:14:38 +11:00
serial.go remove vendor, but fork modbus pkg for now 2021-01-10 15:14:38 +11:00
tcpclient.go remove vendor, but fork modbus pkg for now 2021-01-10 15:14:38 +11:00

go modbus Build Status GoDoc

Fault-tolerant, fail-fast implementation of Modbus protocol in Go.

Supported functions

Bit access:

  • Read Discrete Inputs
  • Read Coils
  • Write Single Coil
  • Write Multiple Coils

16-bit access:

  • Read Input Registers
  • Read Holding Registers
  • Write Single Register
  • Write Multiple Registers
  • Read/Write Multiple Registers
  • Mask Write Register
  • Read FIFO Queue

Supported formats

  • TCP
  • Serial (RTU, ASCII)

Usage

Basic usage:

// Modbus TCP
client := modbus.TCPClient("localhost:502")
// Read input register 9
results, err := client.ReadInputRegisters(8, 1)

// Modbus RTU/ASCII
// Default configuration is 19200, 8, 1, even
client = modbus.RTUClient("/dev/ttyS0")
results, err = client.ReadCoils(2, 1)

Advanced usage:

// Modbus TCP
handler := modbus.NewTCPClientHandler("localhost:502")
handler.Timeout = 10 * time.Second
handler.SlaveId = 0xFF
handler.Logger = log.New(os.Stdout, "test: ", log.LstdFlags)
// Connect manually so that multiple requests are handled in one connection session
err := handler.Connect()
defer handler.Close()

client := modbus.NewClient(handler)
results, err := client.ReadDiscreteInputs(15, 2)
results, err = client.WriteMultipleRegisters(1, 2, []byte{0, 3, 0, 4})
results, err = client.WriteMultipleCoils(5, 10, []byte{4, 3})
// Modbus RTU/ASCII
handler := modbus.NewRTUClientHandler("/dev/ttyUSB0")
handler.BaudRate = 115200
handler.DataBits = 8
handler.Parity = "N"
handler.StopBits = 1
handler.SlaveId = 1
handler.Timeout = 5 * time.Second

err := handler.Connect()
defer handler.Close()

client := modbus.NewClient(handler)
results, err := client.ReadDiscreteInputs(15, 2)